65
When an activation occurs (e.g., Entry), the parking space will not be occupied
until that the vehicle passes through the sensors (inductive loop or photocell)
installed near the door or access door. Thus, after the passage the parking spa-
ce will be occupied. Without any passage through the two sensors, the parking
space will not be occupied.
Apply the “With Validation” parking control settings and adds with the denition of
“Free Exit”, that is, the system does not consider the last access to validate the
exit operation. If the user of the system has entered at a time when the system
was inactive, or hitched on the activation of another user, the door or exit barrier
will be activated normally.
This function allows you to delete the status of the parking space counting re-
cords for all users, that is, when performing this operation, all users will have
their parking spaces freed and the counting process will start again from the next
access. If the rst access is for entry, the user’s parking space will be considered
occupied immediately after the access. In the event that the rst access is an
exit, the system will authorize the exit and wait for the user to return through the
entrance access to account for the occupation of the parking space.
Through the “EVENT FORMATTING” menu, it is possible to select the protocol
for sending events online via the serial port (RS232 for communication with PC)
or secondary TCP/IP. Select “OWNER” to send events in the Nice Brazil stan-
dard or “Contact ID” (Ademco standard - use the HTML page or the Software
Nice Brazil for more congurations).
11.6.10.3 WITH VALIDATION BY PASSAGE EVENT
11.6.10.4 WITH VALIDATION BY PASS EVENT AND FREE EXIT
11.6.10.5 RESET PARKING CONTROL
11.6.11 EVENT FORMATTING
Figura 11.6.11.a