EasyManua.ls Logo

Nikon VBA23001 - Page 170

Nikon VBA23001
219 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VBA23001-R.3762.A
- A88 D90 -
Device
SHUTTER TESTER EF-1(CE)
J19123
LENS AF50/1.4D
J18267
Caution: Whenever the I PCB is replaced, or the main PCB is replaced, make this adjustment.
Aperture accuracy inspection
USB communication
Device
FLASH METER
STANDARD REFLECTOR 1.5M ×1.5M
J18360
Inspection and adjustment of built-in SB light quantity
USB communication
Set the distance between the camera and ash meter to 1m. Then, the built-in SB light quantity is inspected and
adjusted.
Battery check voltage adjustment (
For device and details, refer to Page A71.)
RS232C communication
Inspection/adjustment of AE accuracy
USB communication
Caution: Regarding AE accuracy, inspection is not made by using exposure value with shutter tester as seen in the
traditional method. The metering value will appear on PC screen.
Whenever the metering FPC unit is disassembled/replaced or the main PCB is replaced,
make this adjustment.
Device
SHUTTER TESTER EF-1(CE)
J19123
LENS AF50/1.4D
J18267
LENS AF28/2.8D
LENS AF70-300/4-5.6D OR LENS AF-SVR70-300/4.5-5.6
BODY CAP
EYEPIECE CAP
INC

Table of Contents