- A88 ・ D90 -
Device
SHUTTER TESTER EF-1(CE)
J19123
LENS AF50/1.4D
J18267
Caution: Whenever the I PCB is replaced, or the main PCB is replaced, make this adjustment.
④
Aperture accuracy inspection
《
USB communication
》
Device
FLASH METER
STANDARD REFLECTOR 1.5M ×1.5M
J18360
⑤
Inspection and adjustment of built-in SB light quantity
《
USB communication
》
Set the distance between the camera and ash meter to 1m. Then, the built-in SB light quantity is inspected and
adjusted.
⑥
Battery check voltage adjustment (
For device and details, refer to Page A71.)
《
RS232C communication
》
③
Inspection/adjustment of AE accuracy
《
USB communication
》
Caution: Regarding AE accuracy, inspection is not made by using exposure value with shutter tester as seen in the
traditional method. The metering value will appear on PC screen.
Whenever the metering FPC unit is disassembled/replaced or the main PCB is replaced,
make this adjustment.
Device
SHUTTER TESTER EF-1(CE)
J19123
LENS AF50/1.4D
J18267
LENS AF28/2.8D
LENS AF70-300/4-5.6D OR LENS AF-SVR70-300/4.5-5.6
BODY CAP
EYEPIECE CAP