Setup
WARNING: Allow only qualified personnel to perform the following tasks.
Follow the safety instructions in this document and all other related
documentation.
Feed Center Function Settings
The feed center functions are controlled by a PLC inside the feed center
control panel, on the front of the feed center. The following function values
are programmed into the controller at the factory and can be adjusted as
needed for the application.
Screen Function Description Default
SCREEN 1
Welcome Screen
Displays current version
and date
SCREEN 2
Virgin Powder Transfer
Delay
Sets the time to wait after
the powder level falls
below the level sensor
before turning on the virgin
transfer pump. The virgin
pump and sieve must be
on. This delay prevents
frequent pump starts and
stops (chattering).
40.00
seconds
SCREEN 3
Low Powder Alarm
Delay
Sets the time to wait after
the powder level in the
feed hopper falls below the
level sensor before turning
on the alarm buzzer. The
virgin transfer pump must
be on. If powder is
detected before the timer
runs out, the timer is
cancelled. The buzzer can
be silenced by switching
Gun Purge on momentarily.
3.00
minutes