Calibrating the Sensor
2
Confirm the sensor position.
The “
∆
” indicates the
black mark sensor
position
Position During Regular Usage
Factory setting is this position.
The “│” indicates
the gap sensor
position
Edge of
paper
10 mm from
edge of paper
16.5 mm
from edge
of paper
Edge of
paper
Sensor Position Adjustment Dial
(1)
Check the black mark sensor
position
Align the paper, and check the
actual position of the black mark
and the black mark sensor position.
Black mark (on back
side of paper)
If the position of the black mark
and the black mark sensor position
do not align, rotate the Sensor
Position Adjustment Dial to adjust
the position (go to step 3).
Black mark (on back
side of paper)
The black mark sensor position is
set 10 mm from the edge of the
paper.
If the black mark is 15 mm or
more from the edge of the paper,
you do not need to adjust it.
If the black mark is 15 mm or less
from the edge of the paper, adjust
the position of the
∆
so it is in the
center of the black mark.
(2)
Check the gap sensor position
Align the paper, and check the
actual position of the label and the
gap sensor position.
Label
Liner