- 37 -
Calibrating the Sensor
If You Cannot Set the Sensors from the Printer Driver
If you cannot set the sensors from the printer driver, then set them from the control panel.
Black mark sensor Gap sensor
Confirm the sensor position
Configure the sensor type
Media form = Continuous Paper (Black Mark)
Die-cut Label (Black Mark)
Continuous Label (Black Mark)
Configure the sensor type
Media form = Die-cut Label (Gap)
Configure the paper size
Paper Size = Custom
X Dimension = Input the “label width”
For die-cut labels (black marks):
Paper length = Input the “label length”
Gap Length = Input the “gap length”
Otherwise:
Black mark interval = Input the “length between
black marks”
Configure the paper size
Paper Size = Custom
X Dimension = Input the “label width”
Y Dimension = Input the “label length”
Gap Length = Input the “gap length”
Execute sensor calibration
Sensor calibration
→
Execute