- 38 -
Calibrating the Sensor
Calibrating the Black Mark
Sensor
You can adjust the black marks on roll paper
using the black mark sensor.
Here, we will show the method when Continuous
Label (Black Mark) are used.
1
Press the <Fn> key.
The numerical values input screen will
be displayed.
2
Press <8>, <9>, <1> (function
numbers), and then press the <OK>
button.
3
Select [6. Continuous Label (Black
Mark)], and then press the <OK>
button.
4
Press the <ON LINE> button to return
to the standby screen.
5
Press the <Fn> key, and then press the
following buttons: <9>, <0>, <OK>.
6
On the Paper Size menu, select
[Custom], press the <OK> button, and
then press the <ON LINE> button.
The display will return to the standby
screen.
7
Press the <Fn> key, and then press the
following buttons: <9>, <1>, <OK>.
8
Use the numeric keypad to enter the
label width, press the <OK> button,
and then press the <ON LINE> button.
The display will return to the standby
screen.