Table of Setting Items in the Control Panel Menu Screen
Item Value Description
Sensor
Calibration
Set1 :
Set2 :
Set3 :
Set4 :
Set5 :
Set6 :
Set7 :
Set8 :
Set9 :
Set10 :
Execute Calibration Execute Executes calibration of the gap sensor or
black mark sensor.
Adjust
Slice
Level
Reflective
Sensor in
Unwinder
0
1023
Fine tunes the sensitivity of the reflective
sensor in the unwinder that was measured
during Sensor Calibration.
The default value fluctuates according to
the results of the calibration.
Appears when the black mark sensor is
used.
Reflective
Sensor in
Printer
0
1023
Fine tunes the sensitivity of the reflective
sensor in the device that was measured
during Sensor Calibration.
The default value fluctuates according to
the results of the calibration.
Appears when the black mark sensor is
used.
Transmission
Sensor in
Unwinder
0
1023
Fine tunes the sensitivity of the
transmission sensor in the unwinder that
was measured during Sensor Calibration.
The default value fluctuates according to
the results of the calibration.
Appears when the gap sensor is used.
Transmission
Sensor in
Printer
0
1023
Fine tunes the sensitivity of the
transmission sensor in the device that
was measured during Sensor Calibration.
The default value fluctuates according to
the results of the calibration.
Appears when the gap sensor is used.
Change Name Execute You can change the name of the specified
setting numbers.
You can use up to eight characters of
single-byte upper case English and
numbers.
Reset Setting Execute Initializes the content of the specified
setting numbers.
Check Media Pitch Execute Measures the intervals on the paper.
Appears when the [Media Form] is
something other than [Continuous Paper]
or [Continuous Label].