F-17
Appendices
MicroHAWK V320-F / V330-F / V420-F / V430-F Barcode Reader User Manual
F-10 Capture Mode
F
F-10-3 Number of Continuous Captures
F-10-3 Number of Continuous Captures
Definition:
Specifies the number of captures to process in Continuous Capture mode.
Serial Cmd:
<
K241,
capture mode,
number of captures,rapid capture mode,number of
continuous
captures
,images per read cycle limit,read cycle history>
Default: 2
Options: 1 and 255
F-10-4 Images per Read Cycle Limit
Definition:
Specifies the number of captures to process in a read cycle.
Serial Cmd:
<
K241,
capture mode,
number of captures,rapid capture mode,number of
continuous
captures,
images per read cycle limit
,read cycle history>
Default: 10
Options: 3 and 255
F-10-5 Read Cycle History
Definition:
Specifies the number of images that can be stored in read cycle history.
Serial Cmd:
<
K241,
capture mode,
number of captures,rapid capture mode,number of
continuous
captures,
images per read cycle limit
,read cycle history>
Default: 10
Options: 0 and 255