M-1 Operational Commands
Type Command Name
Counter Request/Clear
<q> No-Reads Per Read Cycle Counter
<q0> No-Reads Per Read Cycle Counter Reset
<$> Mismatch Per Read Cycle Counter
<$0> Mismatch Per Read Cycle Counter Reset
<N> No-Read Counter
<O> No-Read Counter Reset
<T> Trigger Counter
<U> Trigger Counter Reset
<V> Match Code Counter
<W> Match Code Counter Reset
<X> Mismatch Counter
<Y> Mismatch Counter Reset
Firmware Verification
<#> Request All Part Numbers
<#a> Request Application Firmware Part Number
<#b> Request Boot Code Firmware Part Number
<!> Request All Firmware Checksums
<!a> Request Application Firmware Checksum
<!b> Request Boot Code Firmware Checksum
<!s> Request Current Parameter Settings Checksum
Read Rate
<C> Decodes Per Second Test
<Cp> Decode Percent Test
<J> Exit Read Rate Tests
<a1> Preface PDF417 Output with Data Attributes
Device Control
<L1> Pulse Programmable Output 1
<L2> Pulse Programmable Output 2
<L3> Pulse Programmable Output 3
Read Cycle
Enable/Disable
<I> End Current Read Cycle until <H>
<H> Enable Read Cycle after <I>
<l1>
1
Activate Targeting System
<l0>
2
Deactivate Targeting System
Parameter Reset/Save
<A?/1>
Complete Reset when Resets or Save for Power-On
Command Has Been Issued
<A?/0> Warm Reset if Power-On Command Has Been Issued
Resets
<A> Software Reset, Current Parameters Retained
<Ard>
Software Reset, Recall Default Parameters except Commu-
nication and Custom Unit Name Parameters
<Arp> Software Reset, Recall Power-On Default Parameters
<Arc> Software Reset, Recall Customer Default Parameters
1
<l1> = lowercase ‘L’, one
2
<l0> = lowercase ‘L’, zero
Save for Power-On
<Z> Software Reset, Save Current Settings for Power-On
<Zc>
Software Reset, Save Current Settings as Customer
Default Parameters
<Zrc>
Software Reset, Recall Customer Default Parameters
and Save for Power-On
<Zrd>
Software Reset, Recall Microscan Default Parameters
Except Communication and Custom Unit Name Parameters
and
Save for Power-On
<Zrdall>
Software Reset, Recall Microscan Default Parameters
Including Communication and Custom Unit Name
Parameters and Save for Power-On
Master Database
<G> Store Next Symbol Read to Database Index 1
<Gn> Store Next Symbol Read to Database Index n
<NEWM> New Master Load Status
Reader Status <?> Reader Status Request

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron MicroHAWK V320-F and is the answer not in the manual?

Omron MicroHAWK V320-F Specifications

General IconGeneral
BrandOmron
ModelMicroHAWK V320-F
CategoryBarcode Reader
LanguageEnglish

Related product manuals