H-21
Appendices
MicroHAWK V320-F / V330-F / V420-F / V430-F Barcode Reader User Manual
H-12 ISO/IEC 16022 Symbol Quality Output 1
H
H-11-4 Decodes per Trigger Threshold
H-12 ISO/IEC 16022 Symbol Quality
Output 1
Output on Symbol Contrast
Output on Print Growth
Output on Axial Non-Uniformity
Output on Unused Error Correction
Usage: Lets the user know if symbol quality is less than acceptable.
Definition: If enabled, toggles Output 1 to an active state when
Symbol Contrast
Threshold
is met.
Serial Cmd: <
K800,output on symbol contrast
,symbol contrast threshold,output on print
growth,print growth threshold,output on axial non-uniformity,axial non-uniformity
threshold,output on UEC,UEC threshold>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Usage: Lets the user know if symbol quality is less than acceptable.
Definition: If enabled, toggles
Output 1
to an active state when
Print Growth Threshold
is met.
Serial Cmd: <
K800,
output on symbol contrast,symbol contrast threshold,
output on print
growth
,print growth threshold,output on axial non-uniformity,axial non-uniformity
threshold,output on UEC,UEC threshold>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Usage: Lets the user know if symbol quality is less than acceptable.
Definition: If enabled, toggles
Output 1
to an active state when
Axial Non-Uniformity
Threshold
is met.
Serial Cmd: <
K800,
output on symbol contrast,symbol contrast threshold,output on print
growth,print growth threshold,
output on axial non-uniformity
,axial non-uniformity
threshold,output on UEC,UEC threshold>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Usage: Lets the user know if symbol quality is less than acceptable.
Definition: If enabled, toggles
Output 1
to an active state when
UEC Threshold
is met.
Serial Cmd: <
K800,
output on symbol contrast,symbol contrast threshold,output on print
growth,print growth threshold,output on axial non-uniformity,axial non-uniformity
threshold,
output on UEC
,UEC threshold>
Default: Disabled
Options: 0 = Disabled 1 = Enabled