G-15
Appendices
MicroHAWK V320-F / V330-F / V420-F / V430-F Barcode Reader User Manual
G-10 Code 93
G
G-10-1 Fixed Symbol Length Status (Code 93)
G-10 Code 93
Usage: Sometimes used in clinical applications.
Definition: Code 93 is a variable-length, continuous symbology employing four element
widths. Each Code 93 character has nine modules that may be either black
or white. Each character contains three bars and three spaces.
Serial Cmd: <K475,status,fixed symbol length status,symbol length>
Default: Enabled
Options: 0 = Disabled 1 = Enabled
G-10-1 Fixed Symbol Length Status (Code 93)
Definition: When disabled, the reader will accept any Code 93 symbol provided is
doesn’t exceed the system’s maximum capabilities.
When enabled, the reader will reject any Code 93 symbol that doesn’t
match the fixed symbol length.
Serial Cmd: <K475,status,fixed symbol length status,symbol length>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
G-10-2 Symbol Length (Code 93)
Definition: This is the symbol length value against which all Code 93 symbols will be
compared.
Serial Cmd: <K475,status,fixed symbol length status,symbol length>
Default: 10
Options: 1 to 64