G-21
Appendices
MicroHAWK V320-F / V330-F / V420-F / V430-F Barcode Reader User Manual
G-13 Pharmacode
G
G-13-1 Fixed Symbol Length Status (Pharmacode)
G-13 Pharmacode
Usage: Used mostly with packaging for the pharmaceuticals industry.
Definition: Encodes up to five different numbers, each with its own color, which may
be entered in decimal or “binary” format with a 1 represented by a thick bar
and a 0 represented by a thin bar. Bar width is independent of height.
In decimal format, each part can be up to 999,999.
In binary format, each input can have up to 19 ones and zeros.
Important: When Pharmacode is enabled, other linear symbologies will not
decode properly. Disable Pharmacode before reading other linear symbologies.
Serial Cmd: <K477,status,fixed symbol length status,fixed symbol length,minimum
number of bars,bar width status,direction,fixed threshold value,background
color>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
G-13-1 Fixed Symbol Length Status (Pharmacode)
Definition: When enabled, the reader will check the symbol length against the symbol
length field. If disabled, any length will be considered valid.
Serial Cmd: <K477,status,fixed symbol length status,fixed symbol length,minimum
number of bars,bar width status,direction,fixed threshold value,background
color>
Default: Disabled
Options: 0 = Disabled 1 = Enabled
G-13-2 Fixed Symbol Length (Pharmacode)
Definition: Specifies the exact number of bars that must be present for the reader to
recognize and decode the Pharmacode symbol.
Serial Cmd: <K477,status,fixed symbol length status,fixed symbol length,minimum
number of bars,bar width status,direction,fixed threshold value,background
color>
Default: 5
Options: 1 to 16
G-13-3 Minimum Number of Bars (Pharmacode)
Definition: Sets the minimum number of bars that a Pharmacode symbol must have to
be considered valid.
Serial Cmd: <K477,status,fixed symbol length status,fixed symbol length,minimum
number of bars,bar width status,direction,fixed threshold value,back-
ground color>
Default: 4
Options: 1 to 16

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron MicroHAWK V320-F and is the answer not in the manual?

Omron MicroHAWK V320-F Specifications

General IconGeneral
BrandOmron
ModelMicroHAWK V320-F
CategoryBarcode Reader
LanguageEnglish

Related product manuals