M-7 Default/Reset/Save
Understanding and controlling your reader’s active, saved, and default settings is critical to its successful
operation.
Resets (“A” commands) affect only the current settings (active memory) and are not saved for power-on.
Power-on parameters (“Z commands) are saved to NOVRAM and recalled and loaded into current
parameters when power is cycled to the reader or the <Arp> command is issued.
Defaults are Omron Microscan firmware settings or saved customer settings that can be recalled, either
by software or hardware reset.
Customer default parameters (saved by <Zc>) are the same set of parameters as power-on parameters
but are saved in a different, isolated section of NOVRAM. This allows a user essentially to create a
backup set of parameters that can be recalled in the event that the current parameters or power-on
parameters have been accidentally changed or are no longer desired.
It is important to note that a hardware default does not affect customer default parameters. For exam-
ple, a user that has inadvertently changed communication settings and saved them with a <Z> com-
mand, may not know the correct settings or have the capability to communicate within those settings.
By first doing a hardware default to restore the known
Omron Microscan defaults, the user can then
recall the previous customer saved settings with an <Arc> or <Zrc> command.
Omron Microscan default parameters are contained in the firmware and cannot be changed.
Function Serial Cmd
Resets
(not saved
for power-on)
Reset <A>
Reset and Recall Microscan Defaults <Ard>
Reset and Recall Power-On Parameters
<Arp>
Reset and Recall Customer Default Parameters <Arc>
Saved for Power-on
Save Current Settings for Power-On <Z>
Save Current Settings as Customer Default Parameters for Power-On <Zc>
Recall Microscan Default Parameters
and Save for Power-On <Zrd>
Recall Customer Default Parameters and Save for Power-On <Zrc>
M-7-1 Resets
M-7-2 Saved for Power-On
M-7-3 Defaults
M-7-4 Customer Default Parameters
M-7-5 Omron Microscan Default Parameters

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron MicroHAWK V320-F and is the answer not in the manual?

Omron MicroHAWK V320-F Specifications

General IconGeneral
BrandOmron
ModelMicroHAWK V320-F
CategoryBarcode Reader
LanguageEnglish

Related product manuals