EasyManuals Logo

Omron MicroHAWK V320-F User Manual

Omron MicroHAWK V320-F
502 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #369 background imageLoading...
Page #369 background image
Appendices
H-32
MicroHAWK V320-F / V330-F / V420-F / V430-F Barcode Reader User Manual
Defects
Defects Threshold
Decodability
Decodability Threshold
Usage: Lets the user know if symbol quality is less than acceptable.
Definition: If enabled, drives
Output
if grade is under
Defects Threshold.
Serial Cmd: <
K880,
output on overall grade, overall grade threshold, edge determination,
edge determination threshold, decode, decode threshold, contrast, contrast
threshold, min reflectance, min reflectance threshold, min edge contrast, min
edge contrast threshold, modulation, modulation threshold,
defects,
defects
threshold, decodability, decodability threshold, quiet Zone, quiet zone
threshold >
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Usage: Sets the threshold for driving the output.
Definition: Conforms to ISO/IEC 15416 symbol quality grading (A,B,C,D).
Serial Cmd: <
K880,
output on overall grade, overall grade threshold, edge determination,
edge determination threshold, decode, decode threshold, contrast, contrast
threshold, min reflectance, min reflectance threshold, min edge contrast, min
edge contrast threshold, modulation, modulation threshold, defects,
defects
threshold,
decodability, decodability threshold, quiet Zone, quiet zone
threshold >
Default: Grade B
Options: 0 = Grade D
1 = Grade C
2 = Grade B
3 = Grade A
Usage: Lets the user know if symbol quality is less than acceptable.
Definition: If enabled, drives
Output
if grade is under
Decodability Threshold.
Serial Cmd: <
K880,
output on overall grade, overall grade threshold, edge determination,
edge determination threshold, decode, decode threshold, contrast, contrast
threshold, min reflectance, min reflectance threshold, min edge contrast, min
edge contrast threshold, modulation, modulation threshold, defects, defects
threshold,
decodability,
decodability threshold, quiet Zone, quiet zone
threshold >
Default: Disabled
Options: 0 = Disabled 1 = Enabled
Usage: Sets the threshold for driving the output.
Definition: Conforms to ISO/IEC 15416 symbol quality grading (A,B,C,D).
Serial Cmd: <
K880,
output on overall grade, overall grade threshold, edge determination,
edge determination threshold, decode, decode threshold, contrast, contrast
threshold, min reflectance, min reflectance threshold, min edge contrast, min
edge contrast threshold, modulation, modulation threshold, defects, defects
threshold, decodability,
decodability threshold,
quiet Zone, quiet zone
threshold >
Default: Grade B
Options: 0 = Grade D
1 = Grade C
2 = Grade B
3 = Grade A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron MicroHAWK V320-F and is the answer not in the manual?

Omron MicroHAWK V320-F Specifications

General IconGeneral
BrandOmron
ModelMicroHAWK V320-F
CategoryBarcode Reader
LanguageEnglish

Related product manuals