M-15
Appendices
MicroHAWK V320-F / V330-F / V420-F / V430-F Barcode Reader User Manual
M-9 Other Operational Serial Commands
M
M-9-2 Y-Modem Upload Transfer Options
The data collected by the Optimize operation can be saved for a power-on condition, using the <Z>
command.
Format: <UNOPT>: Initiates an Un-Optimize operation.
This command will cause the product to discard any information acquired during a Optimize operation.
The Un-
Optimized state can be saved for a power-on condition, using the <Z> command.
Format: <OPT?>: Responds with Optimize Status
This command will return the current status of the OPT operation.
Response: <OPT,0>: Default, not optimized
<OPT,1>: Optimize operation in-process
<OPT,2>: Symbol optimized
The Optimize state and parameters persist the same as ordinary parameters. Examples:
• A unit in the optimized state has not been saved. A power cycle will remove any optimized state infor-
mation and the unit will come up in its configured state.
• A unit is saved in a optimizing state. The unit will come from power up in the optimizing state and opti-
mize the first symbol read.
• A unit is saved in a optimized state. The unit will come from power up in the optimized state and only
read the optimized symbol type.
• A optimized unit is issued a reset default command <Ard>. The unit will return to an un-optimized
state but if power is cycled will return to its saved state.
<uy,path,filename>
<dy,path,filename>
<op,9> Manages files in a selected directory.
Un-Optimize Symbol
Optimize Status
Optimize Persistence
M-9-2 Y-Modem Upload Transfer Options
M-9-3 Y-Modem Download Transfer Options
M-9-4 Image Library Request
File Source Explanation
(Nothing) All files in “root” directory
/ All files in “root” directory
/saved All files in “saved” directory
*.* All files in all directories
/del Deletes all files in the root directory
/saved/del Deletes all files in the saved directory