Tone Timings
Description Specifies the pattern, in milliseconds, of busy tones using up to 10
whole numbers (off 1, on 1, off 2, on 2…) separated by commas.
Note
It is recommended that you set a value of 60 milliseconds or
more for the first value (off 1).
Value Range 0–16000 (0: Infinite time)
Note
Avoid setting 1–50 for any of the values.
Default Value 60,500,440
Configuration File Reference BUSY_TONE_TIMING (Page 215)
4.6.4.3 Ringing Tone
Tone Frequencies
Description Specifies the dual-tone frequencies,
in hertz, of ringback tones using 2
whole numbers separated by a comma.
Value Range 0, 200–2000 (0: No tone)
Default Value 440,480
Configuration File Reference RINGBACK_TONE_FRQ (Page 216)
Tone Timings
Description Specifies the pattern, in milliseconds, of ringback tones using up to 10
whole numbers (off 1, on 1, off 2, on 2…) separated by commas.
Note
It is recommended that you set a value of 60 milliseconds or
more for the first value (off 1).
Value Range 0–16000 (0: Infinite time)
Note
Avoid setting 1–50 for any of the values.
Default Value 60,2000,3940
Configuration File Reference RINGBACK_TONE_TIMING (Page 217)
138 Administrator Guide Document Version 2013-03
4.6.4 Tone Settings

Table of Contents