REORDER_TONE_GAIN
Value Format Integer
Description Specifies the gain, in decibels, of the reorder tone.
Value Range -24–6
Default Value 0
REORDER_TONE_RPT
Value Format Integer
Description Specifies whether the reorder tone is repeated.
Value Range 0–1
0: No Repeat
1: Repeat
Default Value 1
REORDER_TONE_TIMING
Value Format Comma-separated Integer
Description Specifies the pattern, in milliseconds, of reorder tones using up to 10
whole numbers (off 1, on 1, off 2, on 2…) separated by commas.
Note
It is recommended that you set a value of 60 milliseconds or
more for the first value (off 1).
Value Range 0–16000 (0: Infinite time)
Note
Avoid setting 1–50 for any of the values.
Default Value 60,250,190
Web User Interface Reference Tone Timings (Page 140)
RINGBACK_TONE_FRQ
Value Format Comma-separated Integer
Description Specifies the dual-tone
frequencies,
in hertz, of ringback tones using 2
whole numbers separated by a comma.
Value Range 0, 200–2000 (0: No tone)
Default Value 440,480
Web User Interface Reference Tone Frequencies (Page 138)