Description Selects whether a tone is heard in response to key presses.
Value Range
Y (Enable Key Pad Tone)
N (Disable Key Pad Tone)
Default Value
Y
Web User Interface Reference Key Click Tone (Page 140)
HOLD_AND_CALL_ENABLE
Value Format Boolean
Description Specifies whether or not to enable making a call while having a call on
hold.
Value Range
Y: Hold and Call
N: Hold and Idle
Default Value
Y
HOLD_TRANSFER_OPERATION
Value Format Boolean
Description Specifies the method of transferring calls.
Value Range
Y: Enable (Press the Hold button to transfer a call.)
N: Disable (Press the Transfer button to transfer a call.)
Default Value
N
5.5.2 Tone Settings
DIAL_TONE1_FRQ
Value Format Comma-separated Integer
Description Specifies the dual-tone frequencies, in hertz, of Dial Tone 1 using 2
whole numbers separated by a comma.
Value Range 0, 200–2000 (0: No tone)
Default Value 350,440
Web User Interface Reference Tone Frequencies (Page 136)
DIAL_TONE1_GAIN
Value Format Integer
Description Specifies the gain, in decibels, of Dial Tone 1.
Document Version 2013-03 Administrator Guide 211
5.5.2 Tone Settings