Default Value Empty string
SYSLOG_PORT
Value Format Integer
Description Specifies the port number of the syslog server.
Value Range 1–65535
Default Value 514
SYSLOG_RTPSMLY_INTVL_n
Parameter Name Example SYSLOG_RTPSMLY_INTVL_1, SYSLOG_RTPSMLY_INTVL_2, …,
SYSLOG_RTPSMLY_INTVL
_6
Value Format Integer
Description Specifies the interval, in seconds, to send summarized information of
RTP packets to the syslog server.
Value Range 0, 5–65535 (0: No information sent)
Default Value 20
5.3.4 Firmware Update Settings
FIRM_UPGRADE_ENABLE
Value Format Boolean
Description Specifies whether to perform firmware updates when the unit detects a
newer version of firmware.
Note
Changing this setting may require restarting the unit.
Local firmware updates from the Web user interface (® see
4.7.2 Local Firmware Update) can be performed regardless
of this setting.
Firmware updates using TR-069 can be performed regardless
of this setting.
Value Range
Y
(Enable firmware updates)
N (Disable firmware updates)
Default Value
Y
Web User Interface Reference Enable Firmware Update (Page 146)