REG_EXPIRE_TIME_n
Parameter Name Example REG_EXPIRE_TIME_1, REG_EXPIRE_TIME_2, …,
REG_EXPIRE_TIME
_6
Value Format Integer
Description Specifies the length of time, in seconds, that the registration remains
valid. This value is set in the "Expires
" header of the REGISTER
request.
Value Range 1–4294967295
Default Value 3600
REG_INTERVAL_RATE_n
Parameter Name Example REG_INTERVAL_RATE_1, REG_INTERVAL_RATE_2, …,
REG_INTERVAL_RATE
_6
Value Format Integer
Description Specifies the percentage of the "expires" value after which to refresh
registration
by
sending a new REGISTER message in the same dialog.
Value Range 1–100
Default Value 90
SIP_SESSION_TIME_n
Parameter Name Example SIP_SESSION_TIME_1, SIP_SESSION_TIME_2, …,
SIP_SESSION_TIME
_6
Value Format Integer
Description Specifies the length of time, in seconds, that the unit waits before
terminating SIP sessions when no reply to repeated requests is
received. For details, refer to RFC 4028.
Value Range 0, 60–65535 (0: Disable)
Default Value 0
Web User Interface Reference Supports Session Timer (RFC 4028) (Page 113)
SIP_SESSION_METHOD_n
Parameter Name Example SIP_SESSION_METHOD_1, SIP_SESSION_METHOD_2, …,
SIP_SESSION_METHOD
_6
Value Format Integer
Description Selects the refreshing method of SIP sessions.
Document Version 2013-03 Administrator Guide 251
5.7.2 SIP Settings