CW_ENABLE_n
Parameter Name Example CW_ENABLE_1, CW_ENABLE_2, …, CW_ENABLE_6
Value Format Boolean
Description Specifies whether automatic call waiting is enabled.
Value Range
• Y (Enable Call Waiting)
• N (Disable Call Waiting)
Default Value
Y
RETURN_VOL_SET_DEFAULT_ENABLE
Value Format Boolean
Description Specifies whether the volume is returned to its default setting after each
call.
Value Range
• Y (Volume returns to the default setting after each call)
• N (Volume does not change after each call)
Default Value
N
FLASH_RECALL_TERMINATE
Value Format Boolean
Description Selects the function of the FLASH/RECALL button during a
conversation.
Value Range
• Y (Terminate)
• N (EFA)
Default Value
Y
Web User Interface Reference Flash/Recall Button (Page 125)
FLASHHOOK_CONTENT_TYPE
Value Format String
Description Specifies the type of signal sent when sending a flash hook event.
Value Range
• Signal
• flashhook
Default Value
Signal
Web User Interface Reference Flash Hook Event (Page 126)