SIP_2NDRGSTR_ADDR_n
Parameter Name Example SIP_2NDRGSTR_ADDR_1, SIP_2NDRGSTR_ADDR_2, …,
SIP_2NDRGSTR_ADDR
_6
Value Format String
Description Specifies the IP address of the secondary SIP registrar server.
Note
This setting is available only when "SIP_RGSTR_ADDR_n" is
specified in IP address notation.
Value Range IP address in dotted-decimal notation
Default Value Empty string
SIP_2NDRGSTR_PORT_n
Parameter Name Example SIP_2NDRGSTR_PORT_1, SIP_2NDRGSTR_PORT_2, …,
SIP_2NDRGSTR_PORT
_6
Value Format Integer
Description Specifies the port number to use for communication with the secondary
SIP registrar server.
Value Range 1–65535
Default Value 5060
SIP_TIMER_T1_n
Parameter Name Example SIP_TIMER_T1_1, SIP_TIMER_T1_2
, …, SIP_TIMER_T1_6
Value Format Integer
Description Specifies the default interval, in milliseconds, between transmissions of
SIP messages. For details, refer to RFC 3261.
Value Range
250
500
1000
2000
4000
Default Value 500
Web User Interface Reference T1 Timer (Page 111)
SIP_TIMER_T2_n
Parameter Name Example SIP_TIMER_T2_1, SIP_TIMER_T2_2
, …, SIP_TIMER_T2_6
Value Format Integer
Document Version 2013-03 Administrator Guide 253