Description Specifies the highest port number that the unit will use for RTP packets.
Note
If port numbers are specified in [Channel 1–25] in
4.3.6.3 External RTP Port in the Web user interface, this
setting is ignored and the corresponding external RTP port is
enabled.
Value Range 1424–49150 (even number only)
Note
The value for this setting must be greater than or equal to
"RTP_PORT_MIN" + 400.
Changing this setting may affect the number of simultaneous
calls
that
can be made. Therefore, when setting this parameter,
be aware that the maximum number of necessary ports can be
calculated as shown below:
No. of lines ´ No. of channels ´ 2 ´ 10 (No. of terminals)
Default Value 20000
Web User Interface Reference Maximum RTP Port Number (Page 116)
RTP_PTIME
Value Format Integer
Description Specifies the interval, in milliseconds, between transmissions of RTP
packets.
Value Range
20
30
40
Default Value 20
Web User Interface Reference RTP Packet Time (Page 115)
RTCP_ENABLE_n
Parameter Name Example RTCP_ENABLE_1, RTCP_ENABLE_2
, …, RTCP_ENABLE_6
Value Format Boolean
Description Selects whether to enable or disable RTCP (Real-Time Transport
Control Protocol). For details, refer to RFC 3550.
Value Range
Y (Enable RTCP)
N (Disable RTCP)
Default Value
N
Web User Interface Reference RTCP Enable (Page 118)