Resync Interval
Description Specifies the interval, in minutes, between periodic checks for updates
of the configuration files.
Value Range 1–40320
Default Value 10080
Configuration File Reference CFG_CYCLIC_INTVL (Page 185)
Header Value for Resync Event
Description Specifies the value of the "Event" header sent from the SIP server to
the unit so that the unit can access the configuration files on the
provisioning server.
Value Range Max. 15 characters
Note
You cannot leave this field empty.
Default Value check-sync
Configuration File Reference CFG_RESYNC_FROM_SIP (Page 186)