Value Range
Y (Enable cancelation before registration)
N (Disable cancelation before registration)
Default Value
N
USE_DEL_REG_CLOSE_n
Parameter Name Example USE_DEL_REG_CLOSE_1, USE_DEL_REG_CLOSE_2, …,
USE_DEL_REG_CLOSE
_6
Value Format Boolean
Description Specifies whether to enable the cancelation of registration before the
SIP function shuts down when, for example, the configuration has
changed.
Value Range
Y (Enable registration cancelation before shutting down)
N (Disable registration cancelation before shutting down)
Note
If set to "Y", registration cancelation is enabled.
If set to
"N", registration cancelation is disabled even when the
SIP stack is shutting down.
Default Value
N
PORT_PUNCH_INTVL_n
Parameter Name Example PORT_PUNCH_INTVL_1, PORT_PUNCH_INTVL_2, …,
PORT_PUNCH_INTVL
_6
Value Format Integer
Description Specifies the interval, in seconds, between transmissions of the Keep
Alive
packet
to the unit in order to maintain the NAT binding information.
Note
This setting is available only when "SIP_TRANSPORT_n" is set
to "0" for UDP.
Value Range 0, 10–300 (0: Disable)
Default Value 0
Web User Interface Reference Keep Alive Interval (Page 114)
SIP_ADD_RPORT_n
Parameter Name Example SIP_ADD_RPORT_1, SIP_ADD_RPORT_2, …, SIP_ADD_RPORT_6
Value Format Boolean
Description Selects whether to add the 'rport' parameter to the top Via header field
value of requests generated. For details, refer to RFC 3581.