CFG_RESYNC_DURATION
Value Format Integer
Description Specifies the time period, in minutes, added to "CFG_RESYNC_TIME"
to create a range within which the unit checks for updates of
configuration
files.
The check will be performed at a random time within
this range.
Value Range 0–1439
Default Value 0
CFG_RESYNC_FROM_SIP
Value Format String
Description Specifies the value of the "Event" header sent from the SIP server to
the unit so that the unit can access the configuration files on the
provisioning server.
Value Range Max. 15 characters
Note
An empty string is not allowed.
Default Value check-sync
Web User Interface Reference Header Value for Resync Event (Page 151)
MAINTENANCE_WEB_RESET_ON_STARTUP
Value Format Boolean
Description Performs Reset Web Settings of the parameters below.
FIRM_UPGRADE_ENABLE
FIRM_UPGRADE_AUTO
FIRM_FILE_PATH
PROVISION_ENABLE
CFG_CYCLIC
CFG_CYCLIC_INTVL
CFG_RESYNC_FROM_SIP
CFG_STANDARD_FILE_PATH
CFG_PRODUCT_FILE_PATH
CFG_MASTER_FILE_PATH
Value Range
Y (Enable)
N (Disable)
Default Value
N
186 Administrator Guide Document Version 2013-03
5.3.5 Provisioning Settings