Description Specifies the maximum interval, in seconds, between transmissions of
SIP messages. For details, refer to RFC 3261.
Value Range
2
4
8
16
32
Default Value 4
Web User Interface Reference T2 Timer (Page 111)
SIP_TIMER_T4_n
Parameter Name Example SIP_TIMER_T4_1, SIP_TIMER_T4_2
, …, SIP_TIMER_T4_6
Value Format Integer
Description Specifies the maximum period, in seconds, that a message can remain
on the network.
Value Range
0
1
2
3
4
5
Default Value 0
SIP_FOVR_NORSP_n
Parameter Name Example SIP_FOVR_NORSP_1, SIP_FOVR_NORSP_2, …,
SIP_FOVR_NORSP
_6
Value Format Boolean
Description Specifies whether to perform the fail-over
process
when the unit detects
that the SIP server is not replying to SIP message.
Value Range
Y (Enable fail-over)
N (Disable fail-over)
Note
If set
to "Y", the unit will try to use the other SIP servers via the
DNS SRV and A records.
If set to "N", the unit will not try to use the other SIP servers.
Default Value
Y
254 Administrator Guide Document Version 2013-03