Download Timing Explanation
At a specified time each day After the unit is powered on, it will check for and download configuration
files once per day at the specified time.
SIP Phone
Provisioning
Server
02:00
02:00
Power On
at 12:00
Check
Download
Check
Download
Check
Download
CFG_RESYNC_TIME="02:00"
The configuration files are downloaded at a set time each day:
Set a time by specifying "CFG_RESYNC_TIME".
Note
If the value for "CFG_RESYNC_TIME" is any valid value other
than an
empty string, the unit downloads the configuration files
at the fixed time, and the settings specified in "CFG_CYCLIC",
"CFG_CYCLIC_INTVL", and "CFG_RTRY_INTVL" are
disabled.
The time is specified using a 24-hour clock ("00:00" to "23:59").
When directed When a setting needs to be changed immediately, units can be directed to
download
the
configuration files by sending them a NOTIFY message that
includes a special event from the SIP server.
In the configuration file:
Specify the special event text in "CFG_RESYNC_FROM_SIP".
In the Web user interface:
Click the [Maintenance] tab, click [Provisioning Maintenance],
and then enter the special event text in [Header Value for Resync
Event].
Generally, "check-sync" or "resync" is set as the special event text.