Chapter 6
Power Supply Voltage Detection
Control Register VI - 5
PSVD Control Register 1 (LVICTR1: 0x03F67)
..
The LVIOUT is not sticky bit and it could change after the LVIIRQ is generated.
..
..
To set the PERI1EN.PERI1EN0, more than 1.5 ms is required since the LVION is set to “1”.
To read the LVICTR1.LVIOU, more than 1.5 ms is required since the LVION is set to “1”.
..
bp76543210
Bit name------LVIOUTLVION
At reset00000000
AccessRRRRRRR/WR/W
bp Bite name Description
7-2 - Always read as 0.
1LVIOUT
V
DD30
monitor bit
0: V
DD30
V
LVI
1: V
DD30
V
LVI
0 LVION
PSVD enable control
0: Disabled
1: Enabled