Chapter 17
LCD
XVII - 34 LCD Display Examples
17.4.6 LCD Operation Setup (1/3 duty)
The following example is to display "23" on a 8-segment type LCD panel (two-digit display) through segment
pins, SEG0 to SEG5 and common pins, COM0 to COM2 with 1/3 duty and 1/3 bias, supplied from external volt-
age divider.
The specific settings are as follows;
HCLK: 4 MHz, LCD display clock: HCLK/2
15
(122 Hz), Frame frequency: 41 Hz
Setup Procedure Description
(1) Stop the LCD.
LCDMD2 (0x03E82)
bp7: LCEN = 0
(1) Stop the LCD.
(2) Set a display duty.
LCDMD2 (0x03E82)
bp2-0: LCDDTY2-0 = 010
(2) Set the operation mode to 1/3 duty driving.
(3) Set an LCD clock.
LCDMD3 (0x03E83)
bp6-3: LCCK3-0 = 0100
bp2-0: LCCKS2-0 = 101
(3) Select "HCLK/2
15
" as an LCD clock source.
(4) Set Segment and common output pins.
LCCTR0 (0x03E86)
bp7-4: SEGSL3-0 = 1111
bp2-0: COMSL2-0 = 111
LCCTR1 (0x03E87)
bp3-0: SEGSL7-4 = 1111
LCDSEL (0x03E8E)
bp3-0: COMSL7-4 = 0000
(4) Select SEG0-5 and COM0-2 pins.
(5) Set LCD panel display data.
LCDATA0 (0x03E90) = 0x06
LCDATA1 (0x03E91) = 0x07
LCDATA2 (0x03E92) = 0x00
LCDATA3 (0x03E93) = 0x04
LCDATA4 (0x03E94) = 0x07
LCDATA5 (0x03E95) = 0x02
(5) Set the display data "23" on the segment output latch.
(6) Activate the LCD.
LCDMD2 (0x03E82)
bp7: LCEN = 1
(6) Start the LCD.

Table of Contents