Chapter 4
Clock/ Mode/ Voltage Control
Voltage Control IV - 27
4.3.3 Power Supply Control Register
Power Supply Control Register 0 (PWCTR0: 0x03F6C)
The power supply control register 0 controls the switching V
DD18
output of the power supply generation circuit.
..
Insert 3 NOP instructions right after the instruction to change VDD18 (write instruction to the
PWCTR0.VDDLV1-0).
..
..
When using the instruction to change VDD18, disable the DMA transfer function.
..
..
PWCTR0 register can be update only in SLOW mode.
..
..
The voltage of VDD18 can be changed to match the following conditions.
- “1.1 V to 1.8 V” or “1.8 V to 1.1 V”
- “1.1 V to 1.3 V” or “1.3 V to 1.1 V”
The voltage of VDD18 must not be changed in the following conditions.
- “1.3 V to 1.8 V” or “1.8 V to 1.3 V”
..
bp 76543210
Bit name
Reserved Reserved Reserved Reserved Reserved Reserved VDDLV1
VDDLV0
Initial value10000000
Access R/W R/W R/W R/W R/W R/W R/W R/W
bp Bit name Description
7-2
Reserved
Always set to "000000".
If the value other than 0 is set, this register value is not updated.
1-0 VDDLV1-0
Select output voltage, VDD18
00: 1.1 V
01: 1.3 V
10: 1.8 V
11: Setting is prohibited.