Chapter 13
Serial Interface
XIII - 22 Control Registers
13.2.7 Address Setting Register
SCIFn (n = 2, 3) Address Setting Register (SC2AD, SC3AD)
13.2.8 BRTM Operation Mode Setting Register
BRTM Operation Mode Setting Register (BRTM_S_MD)
bp76543210
Bit name IIC3AD7 IIC3AD6 IIC3AD5 IIC3AD4 IIC3AD3 IIC3AD2 IIC3AD1 IIC3AD0
Initial
value
00000000
Access R/W R/W R/W R/W R/W R/W R/W R/W
bp76543210
Bit name----
BRTM_S3_MD BRTM_S2_MD BRTM_S1_MD BRTM_S0_MD
Initial value 0 0 0 0 0 0 0 0
Access R R R R R/W R/W R/W R/W
bp Bit name Description
7-4 - "0" is always read out
3BRTM_S3_MD
Duty mode of BRTM3 output clock
0: 1:1
1: 1:N
2BRTM_S2_MD
Duty mode of BRTM2 output clock
0: 1:1
1: 1:N
1BRTM_S1_MD
Duty mode of BRTM1 output clock
0: 1:1
1: 1:N
0BRTM_S0_MD
Duty mode of BRTM0 output clock
0: 1:1
1: 1:N
1:1 Duty mode
The period is "2 × (N+1) × Count Clock Period".
1:N Duty mode
The Period is "(N+1) × Count Clock Period". (However, "N = 0" is excluded.)