Chapter 9
16-bit Timer
16-bit High-Precision IGBT Output (with Variable Period/Duty) IX - 55
..
When using the high-precision IGBT output, set the TM7MD2.TM7BCR to "1" to select the
TM7OC1 compare match as the binary counter clear source and the IGBT output set source
(to "High" state). Also, set the TM7MD2.T7PWMSL to "1" to select TM7OC2 compare match
as the IGBT output reset source (to "Low" state).
..
..
The IGBT output at the initial state becomes "Low" when setting the TM7MD3.T7IGBTEN to
select the IGBT output. It changes to "High" at the second count clock cycle from the trigger
input.
..
..
When using the high-precision IGBT output, set the values of TM7OC1 and 2 as follow:
TM7OC2 ≤ TM7OC1
If TMnOC2 > TMnOC1, the IGBT output is fixed to "High".
..
One-shot Pulse Output of High-Precision IGBT (Normal) (Timer 7)
Figure:9.10.4 One-shot Pulse Output of High-Precision IGBT (Normal)
N
M
0000 0001 0002 M-1 M M+2M+1 N-1 N 0000
GBT
rigger
M7IO output
IGBT output)
M8IO output
IGBT output)
ount
lock
M7EN
it
ompare
egister 1
ompare
egister 2
inary
ounter