P o o l C o p M a n u a l : V 4 2 EN P a g e | 29
www.poolcop.com PCFR
Binary Combination
This is option is not related to a specific pump, but can be used to control several mono speed pumps.
Figure 22 Binary combination
Davey ProMaster VSD400
Figure 23 Davey ProMaster VSD400
Speed Pump Aux1 Aux2 Aux3
STOP OFF OFF OFF OFF
1 ON OFF OFF OFF
2 ON ON OFF OFF
3 ON OFF ON OFF
4 ON ON ON OFF
5 ON OFF OFF ON
6 ON ON OFF ON
7 ON OFF ON ON
8 ON ON ON ON
Binary Combination
Speed Pump Aux1 Aux2 Aux3
STOP OFF OFF OFF OFF
1(33%) ON OFF OFF ON
2(50%) ON OFF ON OFF
3(67%) ON ON OFF ON
4(83%) ON ON ON OFF
5(100%) ON ON OFF OFF
BCKWSH ON OFF ON ON
DAVEY ProMaster VSD