EasyManua.ls Logo

PoolCop Evolution - Filtration Modes

PoolCop Evolution
114 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
P o o l C o p M a n u a l : V 4 2 EN P a g e | 57
www.poolcop.com PCFR
Filtration Modes
Program filtration timers and duration, manually or in automatic modes. Whenever quitting the FILTRATION MODES menu,
PoolCop checks and adjust the status of the pump and auxiliaries, and switches them ON or OFF as required to match programmed
running times.
Filtration is stopped. Both Cycle1 and Cycle2 timers
are set to 00:00-00:00.
Cycle1 is free to be set at any value you may
choose. Make sure there is at least 30 min break
between Cycle1 and Cycle2.
Cycle2 is free to be set at any value you may
choose. Make sure there is at least 30 min break
between Cycle1 and Cycle2.
Cycle1 is free to be set at any value you may
choose.
Choose Cycle2 start time, duration is calculated in
accordance with pool needs based on temperature.
Cycle1 duration is taken into account.
Cycle1 is free to be set at any value you may
choose.
Choose Cycle2 start time, duration is calculated in
accordance with pool needs based on turnovers.
Cycle1 duration is taken into account.
Choose Cycle1 start time. Cycle1 and Cycle2
duration are 11:30min fixed value allowing a 23
hour per day filtration duration.
Filtration will run 23 hours for a 24 hours period
and revert back to normal filtration times. Cycle1
timer settings will be changed when entering the
forced mode and restored at the end of period.
Filtration will run 23 hours for a 48 hours period
and revert back to normal filtration times. Cycle1
timer settings will be changed when entering the
forced mode and restored at the end of period.
Filtration will run 23 hours for a 72 hours period
and revert back to normal filtration times. Cycle1
timer settings will be changed when entering the
forced mode and restored at the end of period.
Filtration Modes
Stopped
Cycle1 =00:00-00:00
Cycle2 =00:00-00:00
Timer
Cycle1 =xx:xx-xx:xx
Cycle2 =xx:xx-xx:xx
ECO+
Cycle1 =xx:xx-xx:xx
Cycle2 =xx:xx-CALC
Volume
Cycle1 =xx:xx-xx:xx
Cycle2 =xx:xx-CALC
Continuous
Cycle1 =xx:xx-CALC
Cycle2 =CALC-CALC
Force 24H
Cycle1 =CALC-CALC
Cycle2 =xx:xx-yy:yy
Force 48H
Cycle1 =CALC-CALC
Cycle2 =xx:xx-yy:yy
Force 72H
Cycle1 =CALC-CALC
Cycle2 =xx:xx-yy:yy

Table of Contents