P a g e | 48 P o o l C o p M a n u a l : V 4 2 EN
www.poolcop.com PCFR
Connecting equipment
Connecting a Pool Cover
A pool cover control functionality is available in Equipment settings (see 5.6.6 Equipment for further details). To achieve remote
control, a compatible pool cover drive unit must be connected to the XM8 Extension Module.
Pool Cover will be operated by “pulsing” the Open command or Close command to the drive. Basically, the operating mode will be
able to replace the genuine button or key operated command.
WARNING:
Remote control of a pool cover can cause severe injury.
The user MUST ALWAYS have the pool in direct view when manoeuvring the cover and during opening or
closing operations. The pool must be monitored at all times during the operation of the pool cover to
ensure that no person is in the pool or enters the pool.
The remote control of the pool cover is reserved for maintenance operations carried out by an authorized
technician.
Figure 50 - Pool Cover connexion (control and position)
NOTE:
Refer to the Pool Cover manufacturer wiring diagrams to wire properly the signals.
Aux14 is open command, Aux 15 is close command and In10 is closed position contact.
Figure 51 - Connection example with MecaTecCenter cover