P a g e | 96 P o o l C o p M a n u a l : V 4 2 EN
www.poolcop.com PCFR
Inputs
Set digital inputs identifier and
behaviour
Various inputs can be installed and configured for use with PoolCop.
Text: None
Default Available
Entries: Available;
Thermostat AntiFrz;
Disinf Consumables;
pH Consumables;
Consumables;
Pool Cover;
Salt System;
Filtration Start
Filtration Stop
Jetstream
Sense of Action
The sensor action configures whether the alert action is taken when the circuit is closed (direct action) or open (reverse action).
For example:
If the thermostat contact closed indicates a freezing risk, choose “Action when CLOSED”.
If the level detection senses that consumables are low by opening the contact in the switch, choose “Action when OPEN”.
Configures whether the alert is triggered when the circuit is closed (direct action)
or open (reverse action).
Text: Action:
Default: When CLOSED
Entries: When CLOSED;
When OPEN
Determines whether an Alert is associated with the sensing on the input or not.
If YES, when input is detected, an alert will be displayed on screen and send to
server (if connected to internet)
Text: Alert:
Default: NO
Entries: NO;
YES