P a g e | 78 P o o l C o p M a n u a l : V 4 2 EN
www.poolcop.com PCFR
5.1 PRIOR TO COMMENCING PROGRAMMING
Clean The Filter
Ensure that the filter is properly cleaned.
With a sand filter, carry out a Clean Filter cycle from Manual Operations to enable accurate settings for automated operation.
On completion, verify that the valve position is Filter, and start the pump in Manual Operations.
This allows the PoolCop to stabilize pressures and to measure water temperature and other data.
The filtration system must run (in Filter or Bypass) for at least 10 minutes on first start or after reset to record stable water
temperature for automatic filtration duration calculations.
Check Pool Level
Refill the pool to the normal level, to ensure accurate pressure and other readings.
Test and Balance Water
It is strongly recommended that the pool water be analysed and balanced prior to programming any water treatment features.

Table of Contents