P a g e | 90 P o o l C o p M a n u a l : V 4 2 EN
www.poolcop.com PCFR
5.6 CONFIGURATION MENU
PoolCop configuration menu
CON F I G U R A TION
Pool Data
Pump Data
Filter Data
Inputs
Factory settings
Equipment
S E L E C T
QUIT
Pool Data
Set pool parameters
POO L D A T A
Volume
: 60 m3
Flow Rate
: 15 m3/h
Turnovers
: 2
Protect Frz
: YES
Cover Reduc
: 30%
Pool Type
: Classic
S E L E C T
QUIT
Volume
Enter the pool VOLUME, in cubic meters. This is used for filter duration calculations in
all automatic modes.
10m³ or less is considered a spa for filter duration calculations: hydraulic corrections
are not applied.
Text: Volume
Default: 60
Entries: 1 250
Flow Rate
Enter the FLOW RATE in m
3
/h of the hydraulic circuit with a clean filter. This is used
for filter duration calculations in automatic modes:
Measure the actual hydraulic flow and enter this figure for optimum
performance; or
Use the lowest of the nominal filter rate and the nominal pump rate, less
20% as the entered flow rate.
When programming for use with a variable speed/flow pump, estimate the
average daily flow rate.
Text: Flow Rate
Default: 15
Entries: 1 99
Turnovers
Set the desired TURNOVERS per day. This is used for filter duration calculations in
VOLUME mode.
Text: Turnovers
Default: 2
Entries: 1 10