P a g e | 34 P o o l C o p M a n u a l : V 4 2 EN
www.poolcop.com PCFR
Disinfection
WEAR HAND PROTECTION:
Always wear correct chemical resistant hand protection when handling chemicals.
EYE PROTECTION:
Always wear correct eye protection when handling chemicals.
PoolCop is compatible with all types of water disinfection. Disinfection can be with or without chemicals.
Means of disinfection
3.5.4.1.1 Chemical Injection by dosing pump
Install the equipment or dosing pump, associated suction and injection pipes and connectors as per the manufacturer
supplied installation manual.
Ensure that the correct consumable is installed and secured.
Route the power supply for the equipment via the chosen auxiliary relay or relays in the CCU.
Connect the equipment to the mains power supply as per the manufacturer’s installation manual, ensuring adequate
electrical protection and conformity.
NOTE:
If injection is controlled by ORP sensor, the dosing pump must be controlled by Aux 6 imperatively.
NOTE:
If injection is controlled by temperature / volume (Remnant) any available Aux can be used.
CAUTION:
Respect AUX 6 Relay max Amps rating. Preferred wiring diagram as per figure below, on the right.
Figure 29 example of connecting dosing pump to Aux6
Test and prime the dosing pump, if applicable:
o In MANUAL CONTROL menu, select the respective AUX to ON; the equipment or pump must run.
o Or in WATER AND TREATMENT, ORP CONTROL, select priming ON.