P o o l C o p M a n u a l : V 4 2 EN P a g e | 83
www.poolcop.com PCFR
5.4 WATER AND TREATMENT MENU
Water level, pH and
disinfection settings
WAT E R A N D
TREA TM E N T
Water level control
pH control
ORP Control
Remnant injection
S E L E C T
QUIT
Water Level
Set water level control
parameters. PoolCop can be
configured to automatically
refill and reduce water level.
WAT E R L E V E L
Installed
: YES
Mode
: AUTO
Cont. Refill
: NO
Max Duration
: 60 mn
Draining
:120 sec
S E L E C T
QUIT
When PoolCop is updating the water level, the last known value blinks on the screen. No action will be taken as long as the new
level is not refreshed (displayed level value will stop blinking). An update is performed every 15minutes when the pump is
stopped.
NOTE:
Make sure to keep at least 30 minutes between filtration cycles to allow water level to function properly.
Installed
With INSTALLED: YES, the menu options display and Alerts are activated.
Text: Installed
Default: NO
Entries: YES;
NO
Water level Control Modes
Water level is updated every 15 minutes when the filtration is stopped.
With mode: READ, PoolCop will indicate the water level on the screen but will not
take any action to control it. Should the level be LOW or V_HIGH, an alert will be
displayed.
With mode: REFILL, if the level is LOW the refill system commands the supply valve to
open to refill the pool until the HIGH level is detected. If the level is V_HIGH, an alert
will be displayed but the level will not be reduced.
If the pump starts during refill, the valve will close, and refilling will be postponed until
the next pump OFF period unless CONT. REFILL: YES, in which case pool refilling will
continue with the pump running.
With mode: REDUCE, level will be automatically reduced if V_HIGH. If the level is
LOW, an alert will be displayed but pool will not be refilled.
With mode: AUTO, control combines REFILL and REDUCE functionalities
Text: Mode
Default: Read
Entries: Read;
Refill;
Reduce;
Auto