P a g e | 94 P o o l C o p M a n u a l : V 4 2 EN
www.poolcop.com PCFR
Filter Data
Set filter parameters
FIL T E R DATA
Pressure
: 1.00 bar
Frequency
: 0
Waste Valve
: NO
Cleaning
: MANUAL
Backwash
: 60 Sec
Rinse
: 10 sec
S E L E C T
QUIT
Pressure
Set the pressure at which an alert reminder “REMIND: CLEAN FILTER” is trigger, or
at which automatic Clean Filter cycle will be triggered.
If measured pressure exceeds this threshold pressure for more than 3 minutes, an
alert to clean the filter will be trigger, and an automatic Clean Filter cycle will be
carried out if configured CLEANING: AUTO.
Setting the pressure limit:
Remove/stop the automatic pool cleaner and reset valves.
Ensure that all debris has been removed from the baskets.
If using variable speed pump, set maximum speed or flow programmed.
Let filtration run for a few minutes to expel any air in the system.
Note the base pressure reading on the PoolCop.
Round off to next higher round number and add a 0.10 bar margin.
Text: Pressure
Default: 1.00 bar
Entries: 0.10 1.80 bar
(min = LOW ALERT see 5.6.2.2)
Example
Base pressure noted = 0.88 bar
Round UP = 0.90 bar
Add 0.10 bar = 1.00 bar
If Clean Filter cycles occur too frequently, increase this setting incrementally.
Whenever resetting or adjusting this pressure, ensure that the filter is clean to get an accurate base pressure.
Generally base pressure decreases over time as the filter media deteriorates.
A steadily increasing base pressure indicates that the filter media is clogging.
Periodic
Set the maximum numbers of days between 2 Clean Filter alerts or automatic
cycles.
If the periodic cleaning is not required, select 0 days.
Text: Frequency
Default: 0
Entries: 0 250 days
Waste Valve
Select YES if an automatic waste valve is fitted on the waste line. This valve,
controlled by Aux5, will be opened by PoolCop when the "main" valve is on Waste,
Backwash or Rinse positions.
Text: Waste Valve
Default: NO
Entries: YES;
NO