P o o l C o p M a n u a l : V 4 2 EN P a g e | 85
www.poolcop.com PCFR
pH Control
Set pH control parameters
NOTE:
Make sure to keep at least 30 minutes between filtration cycles to allow pH to work properly.
If INSTALLED: YES, PoolCop will control the pH according to set point value. pH
Control display will be activated; pH Control Alerts will be activated.
If set to NO, these functions are deactivated.
Text: Installed
Default: NO
Entries: YES;
NO
Set the pH Control to reduce or increase pH using the appropriate chemicals.
READ: if your pool has a standalone pH control system or if you do not want
to control pH but get a reading.
PH-: if pH Minus liquid is used.
PH+: if pH Plus liquid is used.
Text: Mode
Default: Read
Entries: Read;
pH+;
pH-
MAX DOSING acts as a security to prevent inadvertent overdosing, initially calculated
with pool volume, can be adjusted. This setting is higher with bigger pools, and with
higher water alkalinity; this setting is lower with larger dosing pumps.
Text: Max Dosing
Default: 5+Pool Volume/4 mi
Entries: 1, 2… 30 min
Set the desired pH value; a typical Setpoint is 7.2.
The ideal Setpoint varies with water treatment options, and according to refill water
types.
Note: this Setpoint is intended for water at 24°C; actual Setpoint will be automatically
corrected according to the actual water temperature (see below).
Text: SetPoint 24°C
Default: 7.2
Entries: 6.5 – 8.0
Setpoint current temperature °C
PoolCop automatically adjusts the required pH Setpoint as a function of temperature
to ensure year-round optimal water treatment. This adjusted Setpoint is displayed
against current water temperature. This corrected Setpoint is the actual value of pH
the PoolCop will aim to maintain.
Text: SetPoint xx °C
Display of Data only
Ensure dosing pump is connected to Aux7 and correctly powered.
Commanding priming ON will activate Aux7 for 60 seconds allowing the dosing pump
to prime. Priming is stopped when quitting the menu or after 60 seconds.
Text: Priming
Default: OFF
Entries: ON;
OFF