P a g e | 88 P o o l C o p M a n u a l : V 4 2 EN
www.poolcop.com PCFR
5.5 MAINTENANCE
Specific parameters dedicated
to pool maintainers.
Allows you to align PoolCop temperature indication to third party equipment like a
heat pump by adding an offset to the temperature indication.
The value between parenthesis is the actual offset.
Text: Temp
Default: 0.0
Entries: -9.9.0°C – 9.9°C;
When an air sensor is connected, defines the air temperature value to start antifreeze
protection.
See 4.4.4.7 Antifreeze Protection for further details.
Text: Air Antifrz
Default: -5°C
Entries: -9°C – 9°C
In service mode, PoolCop stops all its automatic actions. Every connected device
(pump, Auxiliaries, water refill…) is stopped when using this mode.
PoolCop will only respond to manual command.
This mode could be used for passive winterization or during maintenance actions
Text: Service Mode
Default: NO
Entries: YES,
NO
When water temperature decreases some disinfection devices (for e.g. salt systems)
are prone to more rapid wear. However, algae, viruses and bacteria growth slow down
considerably in cold water; reducing the run time of these devices thus serves to
extend their lifespan.
Choose the temperature value to stop all ORP driven disinfection systems.
Should the chosen temperature be 0°C, the protection will be disabled.
Text: Stop Treatmt
Default: 12°C
Entries: 0°C – 18°C
Perform an extra pH reading.
Pump must be stopped to
allow reading.