EasyManua.ls Logo

PoolCop Evolution - Filtration Mode Configuration

PoolCop Evolution
114 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
P o o l C o p M a n u a l : V 4 2 EN P a g e | 79
www.poolcop.com PCFR
5.2 FILTRATION MODE MENU
Set the duration and times for
daily filtration.
FIL TR A T I O N
Mode
: ECO+
Cycle 1 ON
: 02:30
OFF
: 06:45
Cycle 2 ON
: 12:00
OFF
: 18:43 X
:
S E L E C T
QUIT
The filtration timer has two cycles in any 24 hour period, Cycle 1 and Cycle 2; these cycles are pre-set or are available for any setting
depending on the filtration mode selected.
NOTE:
It is recommended to keep at least 2x30min of free time (no filtration) per day. This will permit pH
measurement, periodic filter cleaning, and automatic pool refill if installed.
Mode
Filtration timer has 8 modes of operation
In STOP mode, filtration timers are set to 00:00. The filtration will never run
in automatic mode.
In TIMER mode, filtration Cycle 1 and Cycle 2 times are set by the user.
In ECO+ mode, PoolCop adjusts filtration duration based on measured water
temperature, filtration rates, and other factors. This mode allows PoolCop to
automatically adjust the filtration duration based on changing seasonal and
weather conditions and thus protect water when temperature is high and
save energy if temperature is low.
o Set Cycle 1 as desired. Duration will be taken into account when
calculating Cycle 2 duration.
o Set the Cycle 2 Filtration ON time. PoolCop calculates and sets the OFF
time, with X indicated.
o The duration is automatically calculated based on the average measured
temperatures during filtration in the last 24 hour period.
o Other pool data settings, including pool volume and rate, are used to
correct calculated duration to ensure that adequate filtration is carried
out daily.
VOLUME mode is based on the same model as ECO+ Mode with a
noticeable difference:
o In ECO+ Mode, the filtration duration is calculated is made using the
pool temperature.
o VOLUME Mode does not take temperature into account, but simply use
the turnover rate defined in the Pool data menu to estimate the
filtration time.
In CONTINUOUS mode, Cycle1 and Cycle 2 have the same 11:30 duration
time so that the global filtration is 23/24. The only available setting is the
starting time of Cycle1.
In FORCE mode (24H, 48H or 72H) filtration will run 23/24 for the selected
period and the will revert back to normal setting. Forced mode is achieved
by temporarily setting Cycle 1 timer value so that, added to Cycle 2, the
filtration duration is 23 hours. No timer settings are available in Forced
mode.
Text:
Default: STOP
Modes: STOP;
TIMER;
ECO+;
VOLUME;
CONTINUOUS;
FORCE24H;
FORCE48H;
FORCE72H
NOTE:
ECO+ Mode uses the daily average water temperature to calculate filtration duration. After a Factory Reset
the default filter time is approximately 8 hours, based on an assumed temperature of 20°C.
An updated calculation is performed automatically at 17:00.

Table of Contents