P a g e | 50 P o o l C o p M a n u a l : V 4 2 EN
www.poolcop.com PCFR
Connecting a Jetstream pump
Jetstream pump is usually operated with a pneumatic push button in the pool. If the push button is connected to the XM8
Extension Module, Jetstream will also be operable remotely and user will be able to choose a running duration (see 5.6.6 Equipment
for further details).
Figure 54 - Jetstream connection
NOTE:
Push button signal must be converted in ON/OFF contact before being connect to PoolCop Extension Module.
This is usually done by a pneumatic switch inside the Jetstream electric box.
Aux13 is Jetstream pump command.