P o o l C o p M a n u a l : V 4 2 EN P a g e | 81
www.poolcop.com PCFR
5.3 AUXILIARIES MENU
Operation Modes of auxiliaries
are related to auxiliary names.
Auxiliary timers have one cycle
in any 24 hour period.
AU X 0 1 : P ool C l e a ner
Mode
: Timer
ON
: 02:30
OFF
: 06:45
Slave
: NO
Weekday
: ✓✓✓✓
S E L E C T
QUIT
Whenever quitting the AUXILIARIES menu, PoolCop checks the status of the auxiliaries, and switches them ON or OFF as required
to match programmed running times.
Auxiliary ID
The default auxiliary ID is the Aux number. Each auxiliary can be renamed for ease of
use and identification. The following 15 pre-set names are available for auxiliaries:
Text:
Default: Available
Entries: Available;
Pool Light;
Pool Cleaner;
Pool Heating;
Disinfection;
Salt System;
Remnant;
Transfer pmp;
UV;
Spa;
Fountain;
Bore Hole;
Pool House;
Garden 1;
Garden 2;
Garden 3;
NOTE:
On "rimflow" pools (see 5.6.1.6 Pool Type), an auxiliary whose
identifier is "Transfer Pump" is considered to be a means of
moving the water from the buffer tank to the pool.
The pump controlled by this auxiliary will be set ON automatically
during the water level control phases in order to produce a change
on the water level in the buffer tank.
NOTE:
To change the auxiliary Id, use the up arrow to place the cursor in the title area, then press select to open the
scroll list. Use up and down arrow to select the Id label and pre-set select to validate.
Aux Mode
Manual mode allows manual ON/OFF commands only. No automatic function will
apply.
Timer mode allow to define a start time and a stop time.
Pulse mode allows to manage the ON duration. When the Aux is set ON (manually or
automatically) it will revert to OFF after the defined duration.
When auxiliary is set as heating, 3 additional modes are available:
In Filtration mode, the heater can only operate during programmed filtration hours.
In Priority mode, the filtration pump is forced on for priority heating which will
accelerate the increase of water temperature.
In Schedule the operation of the heater is limited within the period defined by its
own timers. Heating will then only be possible within the defined ON/OFF time range
and if the filtration is running.
Text: Mode
Default: Manual
Entries: Manual
Timer;
Pulse;
Filtration;
Priority;
Schedule

Table of Contents