P a g e | 56 P o o l C o p M a n u a l : V 4 2 EN
www.poolcop.com PCFR
Manual Control
Manually switch the pump ON or OFF at any time (if no
freeze conditions) in the current valve position.
The programmed pump speed can be changed manually
for the rest of the filtration cycle. Programmed speed will
revert for the next cycle.
REQUIRES PUMP TYPE SET TO A VARIABLE SPEED PUMP.
Manually switch auxiliary equipment ON or OFF at any
time, regardless of the SLAVED: YES/NO
configuration.
Ask for water level update which can lead to water refill or a
level reduction. Will stop refilling when refill in ON.
REQUIRES WATER LEVEL CONTROL INSTALLED.
Stops the pump (if ON) and carries out complete cleaning
cycle (backwash and rinse) at any time.
NOT AVAILABLE WITH CLEAN INHIBITED IN
FILTER DATA MENU.
Stops the pump (if ON) and manually rotates the valve to
FILTER position at any time.
Stops the pump (if ON) and manually rotates the valve to
WASTE position at any time.
Stops the pump (if ON) and manually rotates the valve to
CLOSED position at any time.
Stops the pump (if ON) and manually rotates the valve to
BACKWASH position at any time.
NOT AVAILABLE WITH AUTO CLEAN INHIBITED.
Stops the pump (if ON) and manually rotates the valve to
BYPASS position at any time.
Stops the pump (if ON) and manually rotates the valve to
RINSE position at any time.
NOT AVAILABLE WITH AUTO CLEAN INHIBITED.
Manually command equipment such as pool cover or
Jetstream pump
Manual Control
Pump
Switch Pump
ON or OFF
Change
Pump Speed
Auxiliaries
Switch
ON or OFF
Level Adjust Get water level
Clean Filter
Command Cleaning
Cycle
Valve Rotation
Filter
Waste
Closed
Backwash
Bypass
Rinse
Equipment
Command
Equipement