P o o l C o p M a n u a l : V 4 2 EN P a g e | 31
www.poolcop.com PCFR
Remove the blanking plug in the sensor housing and fit the sensor housing, with O-ring.
Remove the liquid filled transport CAP from the sensor.
First fit the white securing cap to the sensor.
Next fit the star lock grab ring, the grab ring must be between 9-9.5cm from the sensor tip.
Next fit the black compression ring
Next fit the white compression ring.
Next fit the O-ring.
Fully insert the sensor into the housing, and secure with the cap.
Tighten the securing cap.
CAUTION:
Do not over-tighten as the electrode is a sensitive device.
Ensure that the cap is sufficiently secure to retain the sensor in place under water pressure.
Remove the plastic cover from the PCB’s.
Connect the sensor wire plug to the top Connection PCB.
Replace and secure the plastic cover.
Open valves and reconnect water supply, whilst checking for leaks.
Reconnect the pump circuit breaker.
Reset the filtration timers and mode as required.
Start the pump from MANUAL CONTROL menu and check for leaks.
Leave the pump running or switch the pump from MANUAL CONTROL menu, as required.