ComBricks User Manual v6.4.0 | January 18| © PROCENTEC 187/219
Technical Data PROFIBUS Slave PBS-001 (101-220210)
Supported protocols
Data delay time
Delay time jitter
100 m at 3 Mbps .. 12 Mbps
DP-V0, DP- V1, DP-V2, FDL, MPI, FMS, PROFIsafe, PROFIdrive
and any other FDL based protocol
2.0 TBit at 9.6 kbps .. 3 Mbps
2.75 TBit at 6 Mbps
3.75 TBit at 12 Mbps
Max. ¼ TBit
Dipswitches
NW0 NW1
LEFT LEFT
RIGHT LEFT
LEFT RIGHT
RIGHT RIGHT
NU
H/S
LEFT / RIGHT
PROFIBUS Network
1
2
3
4
Not Used
Settings
Hardware / Software
LEDs
RDY (ON)
RDY (Flashing)
RUN (ON)
SF (ON)
BF (ON)
Module is ready for operation
Connecting or updating
Internal firmware is OK
System Failure: diagnostics or
configuration mismatch
Bus Failure: not in Data
Exchange with master
Others
Head Station firmware
Operating temperature
Weight
MTBF
At least version 1.275
0 .. 60 °C
120 g
To be defined
Not in Data
Exchange
Firmware OK
Ready for
operation
I/O or config
error
Not used
Dipswitches or
web server settings
Network 1: NW0 = L, NW1 = L
Network 2: NW0 = R, NW1 = L
Network 3: NW0 = L, NW1 = R
Network 4: NW0 = R, NW1 = R

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Procentec ComBricks and is the answer not in the manual?

Procentec ComBricks Specifications

General IconGeneral
BrandProcentec
ModelComBricks
CategorySwitch
LanguageEnglish